Battery Alarm GX Voltage Alarm Panel

Keep battery-bank voltage warnings visible and audible. Battery Alarm GX provides low- and high-voltage alarm indication, adjustable thresholds and a potential-free alarm contact for a compatible installation.

Add a dedicated voltage warning point

The Battery Alarm is a small panel intended to monitor battery-bank voltage and provide audible and visual warnings. It can be useful where the battery bank itself is out of view. A voltage alarm reports threshold conditions; it does not measure remaining amp-hours, guarantee battery state of charge or replace the battery protection system.

Set the correct system voltage first

The manufacturer manual documents 12V and 24V settings. Select the matching system configuration using the specified DIP switches before choosing alarm thresholds. Do not assume this panel supports a 48V battery bank simply because other GX products do. Have the installer check the power connection and full installation requirements for the exact panel.

Adjust thresholds and hysteresis for the battery

Low- and high-voltage alarm levels and low-voltage hysteresis are configured using DIP switches. Hysteresis separates the alarm and recovery conditions, helping avoid repeated switching near a threshold. Use the manual’s setting table and the battery manufacturer’s voltage recommendations. A setting suitable for one chemistry or charging profile may be unsuitable for another.

Use audible and visible indication

The front panel has a high-voltage indicator, standby indicator and low-voltage indicator, plus a buzzer on/off selector. Turning the buzzer off changes audible behavior; it does not correct the underlying battery or charger condition. Arrange the panel so the responsible operator can see the warning and take the action required by the system design.

Integrate the potential-free contact correctly

Victron documents a potential-free contact with normally open and normally closed contacts. The manual identifies the PCB J1 common, normally-open and normally-closed connections. Have the installer confirm contact wiring and the connected circuit requirements; do not use the panel as a direct high-current battery disconnect or assume the alarm contact can carry the load itself.

Understand the GX name and package

This item is the Battery Alarm GX retail panel, not a Cerbo GX communication centre or internet monitoring gateway. The manufacturer drawing gives a 65 × 120 × 40mm panel envelope. Check the drawing and mounting instructions for the installation details. One alarm panel is supplied; any external alarm circuit, battery wiring, protective devices and wall enclosure must be planned separately.

Plan the complete installation

Match the exact model to the equipment, electrical limits and physical space in your project. Product-family names alone do not establish compatibility. Review the linked manufacturer instructions before ordering, and ask Torven Power if the proposed combination is unclear. Batteries, solar panels, inverters, cables, protective devices and installation labor are separate unless explicitly listed as included.

Buying and installation support

Use the specification table to compare this exact SKU with your system plan. Installation should follow the manufacturer instructions and applicable local requirements. Keep the model number, purchase record and commissioning details with your system documents so future service and replacement decisions use the correct equipment. Availability is shown separately on this page; a published listing does not imply a delivery date.

Read the manufacturer documentation · Confirm your system with Torven Power · Plan your power system · Explore compatible system categories

Victron Battery Alarm GX Voltage Alarm Panel — BPA000100010R Victron Energy Victron Battery Alarm GX Voltage Alarm Panel — BPA000100010R

Torven Power Planner

Not sure this product fits your setup?

Build a personalized power plan before you order. We’ll estimate the capacity, output, voltage, runtime, and solar input your setup needs—then connect you with real products from our catalog.

  1. Tell us what you need to power.
  2. Set your runtime and solar goals.
  3. Review products matched to your answers.

Planner results are estimates. Confirm product compatibility and installation requirements before purchase.

Recently Viewed Products