{"product_id":"renogy-200w-shadowflux-anti-shading-n-type-solar-panel-rsp200dc-asr-g1-us","title":"Renogy 200W ShadowFlux N-Type Anti-Shading Solar Panel","description":"\u003c!-- TORVEN_DESCRIPTION_START --\u003e\u003cdiv style=\"margin:0 0 26px;padding:clamp(24px,4vw,40px);border-radius:18px;background:#0B1220;color:#FFFFFF;\"\u003e\n\u003cp style=\"margin:0 0 10px;color:#F1C75B;font-size:13px;font-weight:800;letter-spacing:1.4px;text-transform:uppercase;\"\u003eResilient output for uneven sunlight\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 14px;color:#FFFFFF;font-size:clamp(28px,4vw,40px);line-height:1.15;\"\u003eA 200W N-Type panel designed to reduce partial-shading losses.\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#E5E7EB;font-size:16px;line-height:1.75;\"\u003eThe Renogy RSP200DC-ASR combines N-Type cells with the ShadowFlux interconnection design for rooftop, RV and off-grid installations where passing shade can affect conventional modules.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(180px,1fr));gap:14px;margin:0 0 30px;\"\u003e\n\u003cdiv style=\"padding:18px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\n\u003cstrong style=\"display:block;font-size:24px;color:#0B1220;\"\u003e200W\u003c\/strong\u003e\u003cspan style=\"color:#4B5563;line-height:1.4;\"\u003eRated output\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:18px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\n\u003cstrong style=\"display:block;font-size:24px;color:#0B1220;\"\u003e20.7%\u003c\/strong\u003e\u003cspan style=\"color:#4B5563;line-height:1.4;\"\u003eModule efficiency\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:18px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\n\u003cstrong style=\"display:block;font-size:24px;color:#0B1220;\"\u003e36.5V\u003c\/strong\u003e\u003cspan style=\"color:#4B5563;line-height:1.4;\"\u003eOpen-circuit voltage\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding:18px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\n\u003cstrong style=\"display:block;font-size:24px;color:#0B1220;\"\u003e23.83 lb\u003c\/strong\u003e\u003cspan style=\"color:#4B5563;line-height:1.4;\"\u003eNet weight\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003csection style=\"margin:0 0 24px;\"\u003e\u003ch2 style=\"margin:0 0 12px;color:#0B1220;font-size:28px;line-height:1.25;\"\u003eDesigned for rooftops where partial shade is hard to avoid\u003c\/h2\u003e\n\u003cp style=\"margin:0;color:#243244;font-size:16px;line-height:1.8;\"\u003eShadowFlux uses a cell-level bypass design to reduce the power loss and hot-spot risk caused by point, line, patchy and moving shadows. It is a practical rigid-panel choice when roof vents, racks, antennas, masts, branches or wiring can cross part of the module during the day. It improves behavior in partial shade; it cannot produce normal output in complete shade and still benefits from shade-aware placement.\u003c\/p\u003e\u003c\/section\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(230px,1fr));gap:14px;margin:0 0 30px;\"\u003e\n\u003carticle style=\"padding:22px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\u003ch3 style=\"margin:0 0 9px;color:#0B1220;font-size:19px;line-height:1.35;\"\u003ePartial-shade resilience\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;line-height:1.7;\"\u003eShadowFlux is engineered to keep more of the panel contributing when a portion of the cell field is shaded.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"padding:22px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\u003ch3 style=\"margin:0 0 9px;color:#0B1220;font-size:19px;line-height:1.35;\"\u003e20.7% module efficiency\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;line-height:1.7;\"\u003eN-Type 16BB cell construction delivers the exact-model module-efficiency rating without confusing it with Renogy's separate cell-efficiency claim.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"padding:22px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\u003ch3 style=\"margin:0 0 9px;color:#0B1220;font-size:19px;line-height:1.35;\"\u003eCompact rigid format\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;line-height:1.7;\"\u003eA 49.69 × 30.08-inch footprint fits many RV, marine and cabin roof layouts where usable mounting area is limited.\u003c\/p\u003e\u003c\/article\u003e\u003carticle style=\"padding:22px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\u003ch3 style=\"margin:0 0 9px;color:#0B1220;font-size:19px;line-height:1.35;\"\u003eHigher-voltage PV profile\u003c\/h3\u003e\n\u003cp style=\"margin:0;color:#4B5563;line-height:1.7;\"\u003eA 31.3V operating voltage and 36.5V open-circuit voltage favor MPPT-based system designs with enough input headroom.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(260px,1fr));gap:16px;margin:0 0 30px;\"\u003e\n\u003csection style=\"padding:24px;border-radius:14px;background:#F3F7F8;\"\u003e\u003ch2 style=\"margin:0 0 13px;color:#0B1220;font-size:24px;\"\u003eBest fit for\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:22px;color:#243244;line-height:1.75;\"\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eRV and van roofs affected by vents, racks, antennas or moving shadows\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eMarine and cabin installations with masts, branches or other partial obstructions\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eCompact off-grid arrays built around a compatible MPPT controller\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eBuyers prioritizing partial-shade behavior over rear-side bifacial collection\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection style=\"padding:24px;border:1px solid #F1D58A;border-radius:14px;background:#FFF9E8;\"\u003e\u003ch2 style=\"margin:0 0 13px;color:#0B1220;font-size:24px;\"\u003eCheck before ordering\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:22px;color:#243244;line-height:1.75;\"\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eRenogy recommends MPPT; for one panel, use PV input capacity above 50V and charge-current capacity above 10A\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eConfirm the device accepts 36.5V Voc, 6.86A Isc and 200W, including cold-weather voltage correction\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eCheck connector polarity, wire size, mounting clearance and the 15A maximum series-fuse rating\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eDo not combine it with existing panels based only on wattage; compare all electrical values and optimizer requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\n\u003c\/div\u003e\u003cdiv style=\"margin:0 0 30px;padding:22px 24px;border-left:5px solid #DEA61D;border-radius:10px;background:#FFF9E8;color:#243244;line-height:1.75;\"\u003e\n\u003cstrong style=\"display:block;margin-bottom:5px;color:#0B1220;\"\u003eWhat “anti-shading” means\u003c\/strong\u003eShadowFlux reduces losses from partial shading; it does not create power in full shade. Renogy recommends keeping more than half of the panel in direct sunlight whenever possible.\u003c\/div\u003e\u003csection style=\"margin:0 0 30px;padding:24px;border:1px solid #D7E0E5;border-radius:14px;background:#FFFFFF;\"\u003e\u003ch2 style=\"margin:0 0 13px;color:#0B1220;font-size:24px;\"\u003eWhat's in the box\u003c\/h2\u003e\n\u003cul style=\"margin:0;padding-left:22px;color:#243244;line-height:1.75;\"\u003e\u003cli style=\"margin:0 0 8px;\"\u003eOne Renogy 200W ShadowFlux N-Type rigid solar panel (RSP200DC-ASR-US)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp style=\"margin:14px 0 0;color:#4B5563;line-height:1.65;\"\u003eMounting hardware, cabling, adapters, protection devices, controllers, inverters and batteries are included only when specifically listed above.\u003c\/p\u003e\u003c\/section\u003e\u003csection style=\"margin:30px 0 0;\"\u003e\u003cp style=\"margin:0 0 8px;color:#B7791F;font-size:13px;font-weight:800;letter-spacing:1.1px;text-transform:uppercase;\"\u003eBuyer Questions\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 14px;color:#0B1220;font-size:28px;line-height:1.25;\"\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdiv style=\"border-top:1px solid #E5E7EB;\"\u003e\n\u003cdetails style=\"border-bottom:1px solid #E5E7EB;padding:0;\"\u003e\u003csummary style=\"cursor:pointer;padding:18px 4px;color:#0B1220;font-weight:750;line-height:1.45;\"\u003eDoes ShadowFlux work in complete shade?\u003c\/summary\u003e\u003cp style=\"margin:0;padding:0 4px 18px;color:#4B5563;line-height:1.75;\"\u003eNo. It is designed to reduce loss from partial shading and still requires sunlight to generate useful power.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails style=\"border-bottom:1px solid #E5E7EB;padding:0;\"\u003e\u003csummary style=\"cursor:pointer;padding:18px 4px;color:#0B1220;font-weight:750;line-height:1.45;\"\u003eIs this a 12V or 24V panel?\u003c\/summary\u003e\u003cp style=\"margin:0;padding:0 4px 18px;color:#4B5563;line-height:1.75;\"\u003eIts 36.5V open-circuit voltage supports use with either battery-system class through a properly sized compatible MPPT controller. It is not a conventional low-voltage panel that should connect directly to a battery.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails style=\"border-bottom:1px solid #E5E7EB;padding:0;\"\u003e\u003csummary style=\"cursor:pointer;padding:18px 4px;color:#0B1220;font-weight:750;line-height:1.45;\"\u003eWhat charge controller does Renogy recommend?\u003c\/summary\u003e\u003cp style=\"margin:0;padding:0 4px 18px;color:#4B5563;line-height:1.75;\"\u003eRenogy recommends MPPT. For one panel, it recommends a controller with more than 50V of PV-input capacity and more than 10A of charge-current capacity.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails style=\"border-bottom:1px solid #E5E7EB;padding:0;\"\u003e\u003csummary style=\"cursor:pointer;padding:18px 4px;color:#0B1220;font-weight:750;line-height:1.45;\"\u003eCan it connect to a portable power station?\u003c\/summary\u003e\u003cp style=\"margin:0;padding:0 4px 18px;color:#4B5563;line-height:1.75;\"\u003eOnly if the station accepts the panel's voltage, current, wattage, connector and polarity. Check all five items before connecting it.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails style=\"border-bottom:1px solid #E5E7EB;padding:0;\"\u003e\u003csummary style=\"cursor:pointer;padding:18px 4px;color:#0B1220;font-weight:750;line-height:1.45;\"\u003eCan I combine it with my existing panels?\u003c\/summary\u003e\u003cp style=\"margin:0;padding:0 4px 18px;color:#4B5563;line-height:1.75;\"\u003eOnly after checking electrical matching, string design, controller or inverter limits and any optimizer requirements. A shared 200W label does not make two models electrically interchangeable.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- TORVEN_DESCRIPTION_END --\u003e\u003c!-- TORVEN_SPECIFICATIONS_START --\u003e\u003csection style=\"margin:26px 0;padding:28px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\u003cp style=\"margin:0 0 8px;color:#B7791F;font-size:13px;font-weight:800;letter-spacing:1.2px;text-transform:uppercase;\"\u003eProduct Data\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 14px;color:#0B1220;font-size:26px;line-height:1.25;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;border:1px solid #E5E7EB;border-radius:12px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#0B1220;color:#FFFFFF;\"\u003e\n\u003cth style=\"padding:14px 16px;text-align:left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:14px 16px;text-align:left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eProduct\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003eRenogy 200W ShadowFlux N-Type Anti-Shading Solar Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eTorven SKU\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003eRSP200DC-ASR-G1-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eRenogy model \/ MPN\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003eRSP200DC-ASR-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eRated maximum power\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e200W STC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eCell technology\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003eN-Type monocrystalline, 16BB, ShadowFlux design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eVmp \/ Imp\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e31.3V \/ 6.38A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eVoc \/ Isc\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e36.5V \/ 6.86A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eModule efficiency\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e20.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eMaximum system voltage\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e1000V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eMaximum series fuse\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e-40°F to 185°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e49.69 × 30.08 × 1.18 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eNet weight\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e23.83 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eJunction box \/ connectors\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003eIP67 \/ IP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;border-bottom:1px solid #E5E7EB;\"\u003eMaterials warranty\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;border-bottom:1px solid #E5E7EB;\"\u003e5 years, subject to Renogy's current written terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:12px 16px;text-align:left;\"\u003eOutput warranty\u003c\/th\u003e\n\u003ctd style=\"padding:12px 16px;\"\u003e25 years, subject to Renogy's current written terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:18px 0 0;padding:16px 18px;border-left:4px solid #DEA61D;background:#FFF9E8;color:#243244;line-height:1.65;\"\u003e\n\u003cstrong\u003eInstallation note:\u003c\/strong\u003e Confirm the current Renogy manual and every connected component's limits before installation. Electrical values are stated at standard test conditions unless noted otherwise.\u003c\/div\u003e\n\u003cp style=\"margin:16px 0 0;color:#4B5563;line-height:1.65;\"\u003eNeed help checking fit? \u003ca href=\"\/pages\/contact\" style=\"color:#0B5E75;font-weight:700;\"\u003eContact Torven Power\u003c\/a\u003e with your battery voltage, controller or power-station model, planned panel count and wiring layout.\u003c\/p\u003e\u003c\/section\u003e\u003c!-- TORVEN_SPECIFICATIONS_END --\u003e\u003c!-- TORVEN_WHY_BUY_START --\u003e\u003csection style=\"margin:26px 0;padding:30px;border-radius:14px;background:#0B1220;color:#FFFFFF;\"\u003e\u003cp style=\"margin:0 0 8px;color:#DEA61D;font-size:13px;font-weight:800;letter-spacing:1.2px;text-transform:uppercase;\"\u003eWhy Buy From Us\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 14px;color:#FFFFFF;font-size:26px;\"\u003eClear product data. Real support. Straightforward policies.\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 18px;color:#E5E7EB;line-height:1.7;\"\u003eTorven Power organizes the technical details and helps you confirm system fit before you order.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:12px;\"\u003e\n\u003ca href=\"\/pages\/shipping-policy\" style=\"flex:1 1 210px;padding:20px 16px;border-top:4px solid #DEA61D;border-radius:8px;background:#FFFFFF;text-align:center;text-decoration:none;color:#0D1B2A;\"\u003e\u003cstrong style=\"display:block;margin-bottom:6px;color:#0B1220;\"\u003eShipping Information\u003c\/strong\u003e\u003cspan style=\"display:block;color:#4B5563;line-height:1.45;\"\u003eSee current shipping terms and exclusions.\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/return-refund-policy\" style=\"flex:1 1 210px;padding:20px 16px;border-top:4px solid #DEA61D;border-radius:8px;background:#FFFFFF;text-align:center;text-decoration:none;color:#0D1B2A;\"\u003e\u003cstrong style=\"display:block;margin-bottom:6px;color:#0B1220;\"\u003e30-Day Return Policy\u003c\/strong\u003e\u003cspan style=\"display:block;color:#4B5563;line-height:1.45;\"\u003eReview eligibility, timing and return conditions.\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/price-match\" style=\"flex:1 1 210px;padding:20px 16px;border-top:4px solid #DEA61D;border-radius:8px;background:#FFFFFF;text-align:center;text-decoration:none;color:#0D1B2A;\"\u003e\u003cstrong style=\"display:block;margin-bottom:6px;color:#0B1220;\"\u003ePrice Match Policy\u003c\/strong\u003e\u003cspan style=\"display:block;color:#4B5563;line-height:1.45;\"\u003eReview Torven Power's current price-match terms.\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/contact\" style=\"flex:1 1 210px;padding:20px 16px;border-top:4px solid #DEA61D;border-radius:8px;background:#FFFFFF;text-align:center;text-decoration:none;color:#0D1B2A;\"\u003e\u003cstrong style=\"display:block;margin-bottom:6px;color:#0B1220;\"\u003eReal Customer Support\u003c\/strong\u003e\u003cspan style=\"display:block;color:#4B5563;line-height:1.45;\"\u003eGet pre-purchase product and compatibility guidance.\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003c!-- TORVEN_WHY_BUY_END --\u003e\u003c!-- TORVEN_SHIPPING_START --\u003e\u003csection style=\"margin:26px 0;padding:28px;border:1px solid #E5E7EB;border-radius:14px;background:#FFFFFF;\"\u003e\u003cp style=\"margin:0 0 8px;color:#DEA61D;font-size:13px;font-weight:800;letter-spacing:1.2px;text-transform:uppercase;\"\u003eOrdering Information\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 14px;color:#0B1220;font-size:26px;line-height:1.25;\"\u003eShipping \u0026amp; Returns\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 14px;color:#0D1B2A;line-height:1.7;\"\u003e\u003cstrong\u003eShipping:\u003c\/strong\u003e Free standard shipping applies to eligible products in the contiguous 48 states with no order minimum. Oversized, freight, remote-area, expedited or manufacturer-restricted shipments may require an additional charge. If one applies, Torven Power will contact you for approval before processing the order. Review the \u003ca href=\"\/pages\/shipping-policy\"\u003eShipping Policy\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:0;color:#0D1B2A;line-height:1.7;\"\u003e\u003cstrong\u003eReturns:\u003c\/strong\u003e Return requests are subject to product eligibility, condition, timing and supplier-specific exceptions. Review the \u003ca href=\"\/pages\/return-refund-policy\"\u003eReturn \u0026amp; Refund Policy\u003c\/a\u003e before ordering.\u003c\/p\u003e\u003c\/section\u003e\u003c!-- TORVEN_SHIPPING_END --\u003e","brand":"Renogy","offers":[{"title":"Default Title","offer_id":49096124956927,"sku":"RSP200DC-ASR-G1-US","price":239.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/4812\/9023\/files\/shadowflux-200w-single-clean-no-badge.png?v=1787799827","url":"https:\/\/torvenpower.com\/products\/renogy-200w-shadowflux-anti-shading-n-type-solar-panel-rsp200dc-asr-g1-us","provider":"Torven Power","version":"1.0","type":"link"}